Browse views: by Year, by Function, by GLF, by Subfunction, by Conference, by Journal

Updated recommended lists of genotoxic and non-genotoxic chemicals for assessment of the performance of new or improved genotoxicity tests

Martus, Hans-Joerg (2016) Updated recommended lists of genotoxic and non-genotoxic chemicals for assessment of the performance of new or improved genotoxicity tests. Mutation Research - Genetic Toxicology and Environmental Mutagenesis, 795. pp. 7-30. ISSN 1879-3592

Abstract

In 2008 we published recommendations on chemicals that would be appropriate to evaluate the sensitivity and specificity of new/modified mammalian cell genotoxicity tests, in particular to avoid misleading positive results. In light of new data it is appropriate to update these lists of chemicals. An expert panel was convened and has revised the recommended chemicals to fit the following different sets of characteristics:. •Group 1: chemicals that should be detected as positive in in vitro mammalian cell genotoxicity tests. Chemicals in this group are all in vivo genotoxins at one or more endpoints, either due to DNA-reactive or non DNA-reactive mechanisms. Many are known carcinogens with a mutagenic mode of action, but a sub-class of probable aneugens has been introduced.•Group 2: chemicals that should give negative results in in vitro mammalian cell genotoxicity tests. Chemicals in this group are usually negative in vivo and non-DNA-reactive. They are either non-carcinogenic or rodent carcinogens with a non-mutagenic mode of action.•Group 3: chemicals that should give negative results in in vitro mammalian cell genotoxicity tests, but have been reported to induce gene mutations in mouse lymphoma cells, chromosomal aberrations or micronuclei, often at high concentrations or at high levels of cytotoxicity. Chemicals in this group are generally negative in vivo and negative in the Ames test. They are either non-carcinogenic or rodent carcinogens with an accepted non-mutagenic mode of action. This group contains comments as to any conditions that can be identified under which misleading positive results are likely to occur.This paper, therefore, updates these three recommended lists of chemicals and describes how these should be used for any test evaluation program.

Item Type: Article
Keywords: EURL ECVAM Genotoxicity Improved tests In vitro test Reference chemicals Reliability
Date Deposited: 29 Nov 2017 00:45
Last Modified: 25 Jan 2019 00:45
URI: https://oak.novartis.com/id/eprint/26987

Search